4.2.1.4 Hydraulic fluids. Hydraulic fluids used in the BRU shall be in accordance with
MIL-PRF-83282.
4.2.1.5 Fungus-proof materials. The materials used in the BRU shall be non-nutrients for fungi.
4.2.1.6 Potting compounds. See MIL-HDBK-454, Guideline 47, Encapsulation and
Embedment (Potting) for guidance regarding potting compounds.
4.2.1.7 Corrosion protection. Corrosion protection practices employed shall be in accordance with the MIL-STD-7179 and DoD Corrosion Prevention and Control Planning Guidebook, Spiral 3. Design shall make use of materials that preclude corrosion susceptibility under service environmental conditions without a requirement for hermetic sealing. See
MIL-HDBK-1568 for guidance regarding corrosion prevention materials and processes.
4.2.1.8 Finishes. Protective coatings and finishes shall not crack, chip, or scale during normal service, or in the herein specified extremes of environmental conditions. Surface treatments, coatings, and finishes shall conform to MIL-DTL-5002 or surface treatments specified herein.
4.2.1.8.1 Anodizing. All non-fatigue critical aluminum and aluminum alloy parts, not subject to wear, shall have anodic coatings in accordance with MIL-A-8625, type II. Aluminum and aluminum alloy parts subject to wear shall have anodic coatings in accordance with
MIL-A-8625, type III. On components where anodizing is detrimental to performance, MIL-DTL-81706 shall be used.
4.2.1.8.2 Chemical surface treatment. For aluminum and aluminum alloy parts not subject to wear, abrasion, or corrosion, chemical conversion surface treatment in accordance with
MIL-DTL-5541 may be used in lieu of anodizing.
4.2.1.8.3 Plating. Plating should be avoided. However, when required, plating of steel surfaces shall be in accordance with the requirements of MIL-DTL-5002 or MIL-STD-7179. Steel parts, not subject to wear, in contact with aluminum or aluminum alloys, shall be treated to prevent galvanic action, in accordance with the requirements of MIL-STD-7179.
4.2.1.9 Electrical connectors. The connectors shall contain positive mating features to indicate completed connection and to prevent accidental shorting of or damage to contacts
during mating of the plug and receptacle. Connectors shall contain peripheral grounding fingers that connect the two mating halves of the connector before pin and socket contacts make connection. The connector shall also contain provisions for terminating shield braid for electromagnetic interference protection. The aircraft, weapon and BRU sides of the electrical connection shall contain socket-type contacts and the electrical adapter harness shall contain pin- type contacts. If there is no electrical adapter harness, then the aircraft or BRU side of the