MIL-STD-2088B
w/CHANGE 1
SUMMARY OF CHANGE 1 MODIFICATIONS
1. Added 'SINGLE STORE' to title page of Standard.
2. In Table I, added type III Bomb Rack Unit (BRU) that uses single suspension point with a weight limit of 100 pounds (primarily for Unmanned Aerial Vehicles [UAVs]).
3. Prohibited the use of Materials listed in MIL-HDBK-1587, table I in 4.2.1.1 Metal parts.
4. Changed 4.2.1.6 and 4.2.1.7 - handbooks cited, MIL-HDBK-454 and MIL-HDBK-1568, from requirements to guidance language.
5. Changed MIL-HDBK-454 Guideline 5 to IPC J-STD-001, Class 3 in 4.2.1.11 Soldered or brazed connections.
6. Changed MIL-HBDK-46855 to MIL-STD-46855 in 4.3.9 Human engineering.
7. Added to 4.3.11.1: "Note: Maximum maintenance time applies at the 95th percentile.
8. Added 4.3.12 U.S. Army unique requirements.
9. Added Construct #1 to MIL-STD-130 requirement and serialization requirement for BRU
in 4.5.
10. Added store vertical support requirements for type III BRU to 5.1.2 Store vertical support.
11. Added frangible attachment for Type III BRUs to 5.1.2.1 Vertical Support Latching.
12. Added new Figure 4 Single vertical support spacing, Type III BRU.
13. Added Type III BRU design information to 5.1.4 Fuzing and arming control.
14. Added "and Type III (as applicable)" to 5.1.4.1 Mechanical fuze AUs.
15. Added minimum number of two positive arming attachments for Type III BRUs to 5.1.4.3
Positive arming attachment.
16. Added new table II Store diameters under 5.1.5 Swaybraces, which includes the diameters for Type III BRUs.
17. Added sentence to 5.1.6 Safety interlock stating "A mechanical store support latch interrupt is not required for frangible attach points."
18. Added "(when required)" to third sentence of 5.1.6.1 Safety interlock status. This refers to the mechanical interrupts not required for frangible points (see 17 above).
19. Added 5.1.6.9 Frangible attach point mechanical safety.
20. Added 5.1.6.10 Frangible attach point electrical safety.
21. Changed 5.1.8.1a from Roman numerals to Arabic numbers.
22. Changed 5.1.9.1 from EMCAS to E3 Working Group; EMCPP to E3IAR (E3 Integration and Analysis Report).
23. Minor editing of 5.1.9.2.1 Electromagnetic pulse (EMP).
24. Deleted 5.1.9.6 Wiring and Cabling and renumbered subsequent paragraphs.
25. Deleted 5.1.9.9 Coupling factor (CF).
26. Changed 5.2.6 , line 3, to state: …a current of one ampere for more than 1 second at 23° C
and added " Electric bomb fuzing is not required for Type III BRUs."
27. Added single lug suspensions for manned and unmanned aircraft to 6.1 Intended use.
28. Updated 6.2 Subject term (key word) listing with additional key words.
29. Listing of international standardization agreements changed from Table II to Table III.
30. 6.4 Change notations are now vertical lines versus no marginal notations previously stated.