MIL-STD-2088B
irrespective of its charge level, shall not represent a hazard for ground personnel and shall not physically damage or affect the functionality of surrounding structure and equipment. A built-in safety feature shall exist to prevent the actuation of the pneumatic connection before the
reservoir is safely restrained. The physical removal of the reservoir shall not produce unintended venting or recoil action. If, in order to obtain a safe disconnect, venting is needed at either side
of the pneumatic interface, then a built-in safety feature shall exist to prevent the disconnection until either side is safely vented. Should the BRU inadvertently "fire" during loading and unloading of stores with its pressure vessel charged, all driven items, such as ejectors, shall be precluded from injuring ground personnel or damaging equipment or the aircraft.
5.1.9 Electromagnetic environmental effects (E3). The control of E3 shall be as specified in
5.1.9.1 through 5.1.9.9.
5.1.9.1 Electromagnetic compatibility (EMC) program. A system EMC program in accordance with the requirements of MIL-STD-464 shall be applied. This program shall be supported by an Electromagnetic Compatibility Advisory Board (EMCAB) established in accordance with the requirements of NAVAIR AR-43. The specifics for the EMC program effort are provided in the Electromagnetic Compatibility Program Plan (EMCPP).
5.1.9.2 Electromagnetic interference (EMI). The BRU electrical system shall meet the requirements of MIL-STD-461 Class Alb and MIL-STD-464. For U.S. Army Aviation, the requirements of ADS-37A-PRF, Table 1, parts A and B shall be met.
5.1.9.2.1 Electromagnetic pulse (EMP). The BRU shall meet the EMP requirements of
MIL-STD-464.
5.1.9.3 Electromagnetic vulnerability (EMV). The BRU electrical system shall meet the EMV requirements of MIL-STD-464. For U.S. Army applications the system shall also meet the requirements of ADS-37A-PRF.
5.1.9.4 Lightning protection. The BRU system shall meet the requirements of the EMC program to provide compliance with the requirements of MIL-STD-464 for protection against lightning.
5.1.9.5 Bonding and grounding. The BRU system shall meet the requirements of the EMC
program to provide compliance with the requirements of MIL-STD-464.
5.1.9.6 Wiring and cabling. The BRU shall meet the requirements of the EMC program to provide compliance with the requirements of SAE-AS50881.
5.1.9.7 Static electricity. The BRU system shall meet the requirements of the EMC program to provide compliance with the requirements of MIL-STD-464 for static electricity effects.